Included by Default
1dedicated IPv4 address
Find the address in the server details in the console. If only one address is listed, use it for the first SSH or RDP connection.
Included with the serverUse SSH for Linux and RDP for Windows.
For the first connection after payment and delivery. Use the login address, username and credentials shown in the server details.
First, confirm the account and server, then copy the connection details. The operating system selected at checkout determines the connection method; a payment record alone does not confirm that the server has been delivered.
Open the console and sign in with the account associated with the order. If multiple servers are listed, identify the right one by order number, model and memory tier. Do not use credentials from another server.
Wait until the delivery details are visible, then find the login address and credentials. If connection details are not shown yet, do not guess the username based on the server model or reuse credentials from another server.
Enter the address, username and corresponding credentials in the client. Check for leading or trailing spaces. For a server with multiple addresses, use the first IPv4 address in the list; do not paste the full list into the connection field.
Each server includes 1 dedicated IPv4 address by default. Additional addresses are billed individually per month. Adding addresses does not change which address to use for the initial connection.
1dedicated IPv4 address
Find the address in the server details in the console. If only one address is listed, use it for the first SSH or RDP connection.
Included with the server255maximum additional addresses
Additional IPv4 addresses cost $2/month each and are billed individually. Plan business address allocation and in-system network settings separately; these do not replace the host connection address.
Billed by quantity selected256IPv4 addresses
That is 1 included address plus up to 255 additional addresses. Always use the first address in the list for the initial connection, not an arbitrary business address.
Check address order firstWhen copying an address, include only the address itself—not the list number, comma or any explanatory text. Check the network documentation for information about additional addresses and bandwidth tiers.
In a local SSH client, enter the first IPv4 address and the username shown in the console. The command below uses example field labels; it does not show default account details or a real address.
Replace LOGIN_USER in the command with the login username, and FIRST_IPV4 with the first address. If the client requires other connection parameters, use the information shown in the console rather than guessing defaults.
A host key confirmation prompt may appear on the first connection. Check the target address and verify the fingerprint against a trusted record before proceeding. If a previously recorded key changes, investigate a reinstall or change of target rather than ignoring the warning.
Verify before authenticatingAfter signing in, change the initial password or configure an SSH key. Keep the current session open while changing authentication settings. Test the new method in a separate connection before closing the original session to avoid losing access due to a configuration error.
Test before closing the sessionThe following are examples of Linux commands and output, not live test results. Usernames, addresses and fingerprints are placeholders; device names and system-reported values depend on the server.
$ ssh LOGIN_USER@FIRST_IPV4
The authenticity of host 'FIRST_IPV4' can't be established.
Host key fingerprint: HOST_KEY_FINGERPRINT
Are you sure you want to continue connecting (yes/no/[fingerprint])?
LOGIN_USER@FIRST_IPV4's password:
$ lscpu
CPU(s): 64
Model name: AMD EPYC 7543P 32-Core Processor
$ free -g
total
Mem: 125
$ nvme list
Node Model Namespace Usage
/dev/nvme0n1 NVME_MODEL 1 1 TB
/dev/nvme1n1 NVME_MODEL 1 1 TB
The total value from free -g is the amount of memory recognised by the operating system. A 128GB tier may show about 125, and a 256GB tier about 251; unit conversion and system reservations affect the displayed value. available changes with workload and is not a fixed reading for a memory tier.
The lscpu, free and nvme list examples are for Linux, and the relevant tools must be installed. Use the appropriate system utilities on FreeBSD. Do not format disks, create pools or repartition drives just to reproduce the example output.
Use the remote desktop client included with the local operating system. Enter the first IPv4 address and the credentials shown in the console. If the client has saved details for another account, check which username is actually being submitted.
| Check | Where to Find It | What to Enter |
|---|---|---|
| Remote computer address | IPv4 list in the server details | Enter only the first address. Do not use an additional business address. |
| Username and credentials | Connection details for the same server | Enter the values shown. Do not use the local computer account or a password from another server. |
| OS and licence edition | Order configuration and delivered OS | Windows Server Standard or Datacenter. The edition is the one selected at checkout. |
| System language | Language selected at checkout | English, Traditional Chinese or Simplified Chinese. Interface labels appear in the selected language. |
If a certificate or identity prompt appears, first confirm that the connection target matches the server details; do not dismiss every prompt automatically. After signing in, check the OS version, update the credentials, and confirm that the system firewall and remote access settings meet business requirements. Windows licensing is billed monthly. The licence edition is not determined by the local client's display language.
If SSH or RDP will not connect, first check the first IPv4 address, server status and client error. Then submit a support ticket through the console for assistance.
The standard configuration has two directly attached 1TB NVMe drives, with no hardware RAID. A successful connection confirms access only; it does not mean redundancy or backups are in place.
Check the device identifiers, capacity and mount status of both NVMe drives. System partitions and file systems use space, so the combined advertised capacity of both drives is not a ready-to-use volume. Direct attachment is not a preconfigured RAID-1 array.
Choose software RAID or a ZFS mirror to suit the workload, and confirm the target devices and existing data before making changes. Mirroring reduces usable capacity. Creating an array or storage pool can overwrite existing data, so arrange data migration and backups first.
The account holder is responsible for system configuration, business data and backups. Mirroring is not a substitute for off-site backups. Include recovery tests in the backup plan to confirm that essential data can be restored after accidental deletion, configuration changes or a service failure.
Submit a ticket through the console and include the details from a single connection attempt in one record. The exact error message is more useful than a general description such as “unable to log in” for distinguishing network, host identity and account authentication issues.
Include the order number or server ID, the first IPv4 address used, whether the connection was over SSH or RDP, the target OS and the name of the local client. Note whether the issue occurred on the first login or after a change to the password, key, firewall or network settings.
One set of details per serverPaste the full error message and, if needed, attach a screenshot with sensitive details redacted. Include the fields already checked. Do not paste plaintext passwords, private keys or verification codes into a ticket. Redact account details unrelated to the issue from screenshots.
Keep error text; redact sensitive detailsCheck credentials for an existing server or report connection issues through the console.